ijas
International Journal Of Advances In Surgery

ISSN (O) : 2663 - 046X

A CrossRef Indexed Journal

DOI : 10.34300/26630451

ISSN (P) : 2663 - 0451

IC VALUE : 85.26(2021)

Volume : V, Issue : VI, November - 2021


Original Research Paper

Comparative study of Oxiport laryngoscope blade versus Miller laryngoscope blade for intubation in neonates and infants during general anesthesia-A prospective randomised controlled study.

Nimit Gandhi, Swati Bhatt, Anisha Goswami

Abstract :

Background and Aims:-Neonates and infants are prone to oxygen desaturation during the induction of general anesthesia.Pharyngeal oxygen insufflation has been shown to delay the onset and severity of desaturation during apnea.We took this comparative study with the hypothesis that Oxiport Blade delays the time of onset as well as severity of desaturation as compared to Miller Blade.Material and Methods:-Eighty neonates and infants undergoing general anesthesia with endotracheal intubation were recruited and randomly assigned into two groups:-Oxiport or Miller.(Laryngoscopy performed with Oxiport or Miller Blade respectively).Results were observed in terms of lowest SPO2 attained during Intubation with each Blade, time for 1% desaturation from baseline, desaturation rate, time for intubation and Heart rate.Results:-Data from 80 patients were available for final analysis: Oxiport(n=40)-Group O and Miller(n=40)-Group M.Mean lowest SPO2 attained during laryngoscopy in Group O was 97.772.81 and with Group M was 92.423.71 with a P-value<0.001.The Rate of Saturation achieved in Group O was 0.0910.018 sec as compared to 0.3420.122 sec in Group M and p value was <0.001 .The time for 1% desaturation from baseline in Group O was 17.693.18 sec as compared to 10.4 2.09 sec in Group M with p value<0.001.The time for intubation and average heart rate were comparable in both the groups.Conclusion:-Apnoeic Laryngeal Oxygen insufflation with Oxiport Blade decreases the incidence and severity of desaturation during intubation in neonates and infants.

Keywords :

Apneic oxygenation, endotracheal intubation,infants, Miller Blade, Oxiport Blade, neonates


Cite This Article:

COMPARATIVE STUDY OF OXIPORT LARYNGOSCOPE BLADE VERSUS MILLER LARYNGOSCOPE BLADE FOR INTUBATION IN NEONATES AND INFANTS DURING GENERAL ANESTHESIA-A PROSPECTIVE RANDOMISED CONTROLLED STUDY., Nimit Gandhi, Swati Bhatt, Anisha Goswami, INTERNATIONAL JOURNAL OF ADVANCED MEDICINE : Volume-5 | Issue-6 | November-2021

References :


[ Download PDF ] [ Number of Downloads : 1330 ]

Authors
This work is licensed under a Creative Commons Attribution 4.0 International License.
Disclaimer: Articles on International Journal of Advances In Surgery have been previewed and authenticated by the Authors before sending the publication for print.
The Journal, Editor and the Board of Members are not entitled or liable to either justify or responsible for inaccurate and misleading data if any.
It is the sole responsibility of the Author concerned. If any queries or infringement occurs

Copyrights © 2023: International Journal of Advances In Surgery (IJAS)